Stickstoff-Lecksuche

Stickstoff-Lecksuche

  • Allows for the safe storage and transportation of 10 l nitrogen cylinders
  • Robust and practical design, with hose suspension and integrated box for stowing accessories
  • Easy to use with smooth-running solid rubber wheels

  • Enables safe and controlled admission of nitrogen to A/C systems – ideal for checking for leaks using the differential pressure method
  • Adjustment range of 0–35 bar, making it also suitable for flushing
  • High quality design – durable and reliable
  • Supplied with service quick coupler, 1.8 m service hose for low-pressure side and 1/4" SAE to 1/2" ACME adapter
  • Approved by automotive manufacturers

  • For inspections on A/C evaporators and complete A/C systems in installed condition
  • Manometer block with vent valve and safety valves; 36 bar opening pressure
  • Nitrogen pressure reducer, adjustable from 0–35 bar
  • Test manometer 0–40 bar, calibration: 1 bar, class 1.0
  • Supplied complete with service quick coupler, 1.8 m service hose for low side, 1/4" SAE to 1/2" ACME adapter and cylinder trolley for manometer block

  • Enables safe and controlled admission of nitrogen to A/C systems – ideal for checking for leaks using the differential pressure method
  • Adjustable pressure range of 0–20 bar, making it ideal for air conditioner inspections
  • Complies with the requirements outlined in Section Five of the German Chemicals Climate Protection Ordinance
  • Hose set with couplers available as an optional accessory

  • For controlled and safe admission of nitrogen to A/C systems (pressure test)
  • Specially designed for carrying out nitrogen pressure tests on R1234yf A/C systems
  • Complete set includes service couplers, adapters and hoses for the high-pressure and low-pressure side

Clear all 

Select items to compare Compare 

Hier wird ein Überdruck mit Stickstoff oder ein Unterdruck mittels Vakuum über das Klimaservicegerät erzeugt. Die Lecksuche über eine solche Druckänderung bietet sich vor allem zur Erstdiagnose bei stark undichten oder gar leeren Anlagen an, da nur festgestellt werden kann, dass die Anlage leckt – aber nicht, wo das Leck ist. Die Suche ist nur möglich mit Klimaservicegeräten, die den Prozess automatisch stoppen, wenn sich kein Vakuum erzeugen lässt (z. B. alle Dometic ASC-Stationen).

Läuft der Prozess ohne Fehlermeldung weiter, können Sie sicher sein, dass die Anlage kein Leck hat und ohne Bedenken Kältemittel auffüllen. Der Chemikalien-Schutzverordnung ist damit Genüge getan.