Detección de fugas por presión de nitrógeno

Detección de fugas por presión de nitrógeno

  • Allows for the safe storage and transportation of 10 l nitrogen cylinders
  • Robust and practical design, with hose suspension and integrated box for stowing accessories
  • Easy to use with smooth-running solid rubber wheels

  • Enables safe and controlled admission of nitrogen to A/C systems – ideal for checking for leaks using the differential pressure method
  • Adjustment range of 0–35 bar, making it also suitable for flushing
  • High quality design – durable and reliable
  • Supplied with service quick coupler, 1.8 m service hose for low-pressure side and 1/4" SAE to 1/2" ACME adapter
  • Approved by automotive manufacturers

  • For inspections on A/C evaporators and complete A/C systems in installed condition
  • Manometer block with vent valve and safety valves; 36 bar opening pressure
  • Nitrogen pressure reducer, adjustable from 0–35 bar
  • Test manometer 0–40 bar, calibration: 1 bar, class 1.0
  • Supplied complete with service quick coupler, 1.8 m service hose for low side, 1/4" SAE to 1/2" ACME adapter and cylinder trolley for manometer block

  • Enables safe and controlled admission of nitrogen to A/C systems – ideal for checking for leaks using the differential pressure method
  • Adjustable pressure range of 0–20 bar, making it ideal for air conditioner inspections
  • Complies with the requirements outlined in Section Five of the German Chemicals Climate Protection Ordinance
  • Hose set with couplers available as an optional accessory

  • For controlled and safe admission of nitrogen to A/C systems (pressure test)
  • Specially designed for carrying out nitrogen pressure tests on R1234yf A/C systems
  • Complete set includes service couplers, adapters and hoses for the high-pressure and low-pressure side

Clear all 

Select items to compare Compare 

Este método implica la producción de presión positiva mediante nitrógeno o presión negativa mediante vacío por parte de la estación de mantenimiento de aire acondicionado. La detección de fugas mediante presión diferencial es por lo general apta para la comprobación inicial de sistemas con muchas fugas o incluso vacíos. Únicamente indica que el sistema tiene fugas, no su localización. La comprobación únicamente es posible con estaciones de mantenimiento de aire acondicionado que se detengan automáticamente cuando detectan que es imposible generar vacío (p. ej., todas las estaciones de mantenimiento de aire acondicionado ASC de WAECO).

Si el proceso continúa sin dar aviso de fallo, se cuenta con la seguridad de que el sistema no tiene fugas y se puede cargar con refrigerante. Se cumplen los requisitos de la Ordenanza sobre protección del clima en materia de sustancias químicas.